Contents
Images
Upload your image
DSS Images Other Images
Related articles
Extended envelopes around Galactic Cepheids. I. ℓ Carinae from near and mid-infrared interferometry with the VLTI We present the results of long-baseline interferometric observations ofthe bright southern Cepheid ℓ Carinae in the infrared N (8-13 μm)and K (2.0-2.4 μm) bands, using the MIDI and VINCI instruments of theVLT Interferometer. We resolve in the N band a large circumstellarenvelope (CSE) that we model with a Gaussian of 3 Rstar(≈500 Rȯ ≈ 2-3 AU) half width at half maximum. Thesignature of this envelope is also detected in our K band data as adeviation from a single limb darkened disk visibility function. Thesuperimposition of a Gaussian CSE on the limb darkened disk model of theCepheid star results in a significantly better fit of our VINCI data.The extracted CSE parameters in the K band are a half width at halfmaximum of 2 Rstar, comparable to the N band model, and atotal brightness of 4% of the stellar photosphere. A possibility is thatthis CSE is linked to the relatively large mass loss rate of ℓ Car.Though its physical nature cannot be determined from our data, wediscuss an analogy with the molecular envelopes of RV Tauri, redsupergiants and Miras.
| First results from the ESO VLTI calibrators program The ESO Very Large Telescope Interferometer (VLTI) is one of the leadinginterferometric facilities. It is equipped with several 8.2 and 1.8 mtelescopes, a large number of baselines up to 200 m, and with severalsubsystems designed to enable high quality measurements and to improvesignificantly the limits of sensitivities currently available tolong-baseline interferometry. The full scientific potential of the VLTIcan be exploited only if a consistent set of good quality calibrators isavailable. For this, a large number of observations of potentialcalibrators have been obtained during the commissioning phase of theVLTI. These data are publicly available. We briefly describe theinterferometer, the VINCI instrument used for the observations, the dataflow from acquisition to processed results, and we present and commenton the volume of observations gathered and scrutinized. The result is alist of 191 calibrator candidates, for which a total of 12 066observations can be deemed of satisfactory quality. We present a generalstatistical analysis of this sample, using as a starting point theangular diameters previously available in the literature. We derive thegeneral characteristics of the VLTI transfer function, and its trendwith time in the period 2001 through mid-2004. A second paper will bedevoted to a detailed investigation of a selected sample, aimed atestablishing a VLTI-based homogeneous system of calibrators.
| CHARM2: An updated Catalog of High Angular Resolution Measurements We present an update of the Catalog of High Angular ResolutionMeasurements (CHARM, Richichi & Percheron \cite{CHARM}, A&A,386, 492), which includes results available until July 2004. CHARM2 is acompilation of direct measurements by high angular resolution methods,as well as indirect estimates of stellar diameters. Its main goal is toprovide a reference list of sources which can be used for calibrationand verification observations with long-baseline optical and near-IRinterferometers. Single and binary stars are included, as are complexobjects from circumstellar shells to extragalactic sources. The presentupdate provides an increase of almost a factor of two over the previousedition. Additionally, it includes several corrections and improvements,as well as a cross-check with the valuable public release observationsof the ESO Very Large Telescope Interferometer (VLTI). A total of 8231entries for 3238 unique sources are now present in CHARM2. Thisrepresents an increase of a factor of 3.4 and 2.0, respectively, overthe contents of the previous version of CHARM.The catalog is only available in electronic form at the CDS viaanonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/431/773
| Improved Baade-Wesselink surface brightness relations Recent, and older accurate, data on (limb-darkened) angular diameters iscompiled for 221 stars, as well as BVRIJK[12][25] magnitudes for thoseobjects, when available. Nine stars (all M-giants or supergiants)showing excess in the [12-25] colour are excluded from the analysis asthis may indicate the presence of dust influencing the optical andnear-infrared colours as well. Based on this large sample,Baade-Wesselink surface brightness (SB) relations are presented fordwarfs, giants, supergiants and dwarfs in the optical and near-infrared.M-giants are found to follow different SB relations from non-M-giants,in particular in V versus V-R. The preferred relation for non-M-giantsis compared to the earlier relation by Fouqué and Gieren (basedon 10 stars) and Nordgren et al. (based on 57 stars). Increasing thesample size does not lead to a lower rms value. It is shown that theresiduals do not correlate with metallicity at a significant level. Thefinally adopted observed angular diameters are compared to thosepredicted by Cohen et al. for 45 stars in common, and there isreasonable overall, and good agreement when θ < 6 mas.Finally, I comment on the common practice in the literature to average,and then fix, the zero-point of the V versus V-K, V versus V-R and Kversus J-K relations, and then rederive the slopes. Such a commonzero-point at zero colour is not expected from model atmospheres for theV-R colour and depends on gravity. Relations derived in this way may bebiased.
| Cepheid distances from infrared long-baseline interferometry. I. VINCI/VLTI observations of seven Galactic Cepheids We report the angular diameter measurements of seven classical Cepheids,X Sgr, η Aql, W Sgr, ζ Gem, β Dor, Y Oph and ℓ Carthat we have obtained with the VINCI instrument, installed at ESO's VLTInterferometer (VLTI). We also present reprocessed archive data obtainedwith the FLUOR/IOTA instrument on ζ Gem, in order to improve thephase coverage of our observations. We obtain average limb darkenedangular diameter values of /line{θLD}[X Sgr] = 1.471± 0.033 mas, /line{θLD[η Aql] = 1.839± 0.028 mas, /line{θLD}[W Sgr] = 1.312 ±0.029 mas, /line{θLD}[β Dor] = 1.891 ±0.024 mas, /line{θLD}[ζ Gem] =1.747 ±0.061 mas, /line{θLD}[Y Oph] = 1.437 ± 0.040mas, and /line{θLD}[ℓ Car] = 2.988 ± 0.012mas. For four of these stars, η Aql, W Sgr, β Dor, and ℓCar, we detect the pulsational variation of their angular diameter. Thisenables us to compute directly their distances, using a modified versionof the Baade-Wesselink method: d[η Aql] =276+55-38 pc, d[W Sgr] =379+216-130 pc, d[β Dor] =345+175-80 pc, d[ℓ Car] =603+24-19 pc. The stated error bars arestatistical in nature. Applying a hybrid method, that makes use of theGieren et al. (\cite{gieren98}) Period-Radius relation to estimate thelinear diameters, we obtain the following distances (statistical andsystematic error bars are mentioned): d[X Sgr] = 324 ± 7 ±17 pc, d[η Aql] = 264 ± 4 ± 14 pc, d[W Sgr] = 386± 9 ± 21 pc, d[β Dor] = 326 ± 4 ± 19pc, d[ζ Gem] = 360 ± 13 ± 22 pc, d[Y Oph] = 648± 17 ± 47 pc, d[ℓ Car] = 542 ± 2 ± 49pc.Tables 3 to 10 are only available in electronic form athttp://www.edpsciences.org
| J - K DENIS photometry of a VLTI-selected sample of bright southern stars We present a photometric survey of bright southern stars carried outusing the DENIS instrument equipped with attenuating filters. Theobservations were carried out not using the survey mode of DENIS, butwith individual target pointings. This project was stimulated by theneed to obtain near-infrared photometry of stars to be used in earlycommissioning observations of the ESO Very Large TelescopeInterferometer, and in particular to establish a network of brightcalibrator sources.We stress that near-infrared photometry is peculiarly lacking for manybright stars. These stars are saturated in 2MASS as well as in regularDENIS observations. The only other observations available for brightinfrared stars are those of the Two Micron Sky Survey dating from overthirty years ago. These were restricted to declinations above≈-30°, and thus cover only about half of the sky accessible fromthe VLTI site.We note that the final 2MASS data release includes photometry of brightstars, obtained by means of point-spread function fitting. However, thismethod only achieves about 30% accuracy, which is not sufficient formost applications.In this work, we present photometry for over 600 stars, each with atleast one and up to eight measurements, in the J and K filters. Typicalaccuracy is at the level of 0\fm05 and 0\fm04 in the J and K_s bands,respectively.Based on observations collected at the European Southern Observatory, LaSilla.Tables 1 and 2 are only available in electronic form at the CDS viaanonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or viahttp://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/413/1037
| A catalogue of calibrator stars for long baseline stellar interferometry Long baseline stellar interferometry shares with other techniques theneed for calibrator stars in order to correct for instrumental andatmospheric effects. We present a catalogue of 374 stars carefullyselected to be used for that purpose in the near infrared. Owing toseveral convergent criteria with the work of Cohen et al.(\cite{cohen99}), this catalogue is in essence a subset of theirself-consistent all-sky network of spectro-photometric calibrator stars.For every star, we provide the angular limb-darkened diameter, uniformdisc angular diameters in the J, H and K bands, the Johnson photometryand other useful parameters. Most stars are type III giants withspectral types K or M0, magnitudes V=3-7 and K=0-3. Their angularlimb-darkened diameters range from 1 to 3 mas with a median uncertaintyas low as 1.2%. The median distance from a given point on the sky to theclosest reference is 5.2degr , whereas this distance never exceeds16.4degr for any celestial location. The catalogue is only available inelectronic form at the CDS via anonymous ftp to cdsarc.u-strasbg.fr(130.79.128.5) or viahttp://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/393/183
| CHARM: A Catalog of High Angular Resolution Measurements The Catalog of High Angular Resolution Measurements (CHARM) includesmost of the measurements obtained by the techniques of lunaroccultations and long-baseline interferometry at visual and infraredwavelengths, which have appeared in the literature or have otherwisebeen made public until mid-2001. A total of 2432 measurements of 1625sources are included, along with extensive auxiliary information. Inparticular, visual and infrared photometry is included for almost allthe sources. This has been partly extracted from currently availablecatalogs, and partly obtained specifically for CHARM. The main aim is toprovide a compilation of sources which could be used as calibrators orfor science verification purposes by the new generation of largeground-based facilities such as the ESO Very Large Interferometer andthe Keck Interferometer. The Catalog is available in electronic form atthe CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or viahttp://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/386/492, and from theauthors on CD-Rom.
| Catalogue of Apparent Diameters and Absolute Radii of Stars (CADARS) - Third edition - Comments and statistics The Catalogue, available at the Centre de Données Stellaires deStrasbourg, consists of 13 573 records concerning the results obtainedfrom different methods for 7778 stars, reported in the literature. Thefollowing data are listed for each star: identifications, apparentmagnitude, spectral type, apparent diameter in arcsec, absolute radiusin solar units, method of determination, reference, remarks. Commentsand statistics obtained from CADARS are given. The Catalogue isavailable in electronic form at the CDS via anonymous ftp tocdsarc.u-strasbg.fr (130.79.128.5) or viahttp://cdsweb.u-strasbg.fr/cgi-bin/qcar?J/A+A/367/521
| Research Note Hipparcos photometry: The least variable stars The data known as the Hipparcos Photometry obtained with the Hipparcossatellite have been investigated to find those stars which are leastvariable. Such stars are excellent candidates to serve as standards forphotometric systems. Their spectral types suggest in which parts of theHR diagrams stars are most constant. In some cases these values stronglyindicate that previous ground based studies claiming photometricvariability are incorrect or that the level of stellar activity haschanged. Table 2 is only available in electronic form at the CDS viaanonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or viahttp://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/367/297
| The proper motions of fundamental stars. I. 1535 stars from the Basic FK5 A direct combination of the positions given in the HIPPARCOS cataloguewith astrometric ground-based catalogues having epochs later than 1939allows us to obtain new proper motions for the 1535 stars of the BasicFK5. The results are presented as the catalogue Proper Motions ofFundamental Stars (PMFS), Part I. The median precision of the propermotions is 0.5 mas/year for mu alpha cos delta and 0.7mas/year for mu delta . The non-linear motions of thephotocentres of a few hundred astrometric binaries are separated intotheir linear and elliptic motions. Since the PMFS proper motions do notinclude the information given by the proper motions from othercatalogues (HIPPARCOS, FK5, FK6, etc.) this catalogue can be used as anindependent source of the proper motions of the fundamental stars.Catalogue (Table 3) is only available at the CDS via anonymous ftp tocdsarc.u-strasbg.fr (130.79.128.5) or viahttp://cdsweb.u-strastg.fr/cgi-bin/qcat?J/A+A/365/222
| Sixth Catalogue of Fundamental Stars (FK6). Part I. Basic fundamental stars with direct solutions The FK6 is a suitable combination of the results of the HIPPARCOSastrometry satellite with ground-based data, measured over more than twocenturies and summarized in the FK5. Part I of the FK6 (abbreviatedFK6(I)) contains 878 basic fundamental stars with direct solutions. Suchdirect solutions are appropriate for single stars or for objects whichcan be treated like single stars. From the 878 stars in Part I, we haveselected 340 objects as "astrometrically excellent stars", since theirinstantaneous proper motions and mean (time-averaged) ones do not differsignificantly. Hence most of the astrometrically excellent stars arewell-behaving "single-star candidates" with good astrometric data. Thesestars are most suited for high-precision astrometry. On the other hand,199 of the stars in Part I are Δμ binaries in the sense ofWielen et al. (1999). Many of them are newly discovered probablebinaries with no other hitherto known indication of binarity. The FK6gives, besides the classical "single-star mode" solutions (SI mode),other solutions which take into account the fact that hidden astrometricbinaries among "apparently single-stars" introduce sizable "cosmicerrors" into the quasi-instantaneously measured HIPPARCOS proper motionsand positions. The FK6 gives in addition to the SI mode the "long-termprediction (LTP) mode" and the "short-term prediction (STP) mode". TheseLTP and STP modes are on average the most precise solutions forapparently single stars, depending on the epoch difference with respectto the HIPPARCOS epoch of about 1991. The typical mean error of anFK6(I) proper motion in the single-star mode is 0.35 mas/year. This isabout a factor of two better than the typical HIPPARCOS errors for thesestars of 0.67 mas/year. In the long-term prediction mode, in whichcosmic errors are taken into account, the FK6(I) proper motions have atypical mean error of 0.50 mas/year, which is by a factor of more than 4better than the corresponding error for the HIPPARCOS values of 2.21mas/year (cosmic errors included).
| Spectroscopic binary orbits from photoelectric radial velocities. Paper 148: HR 7955 Not Available
| Spectral Irradiance Calibration in the Infrared. X. A Self-Consistent Radiometric All-Sky Network of Absolutely Calibrated Stellar Spectra We start from our six absolutely calibrated continuous stellar spectrafrom 1.2 to 35 μm for K0, K1.5, K3, K5, and M0 giants. These wereconstructed as far as possible from actual observed spectral fragmentstaken from the ground, the Kuiper Airborne Observatory, and the IRAS LowResolution Spectrometer, and all have a common calibration pedigree.From these we spawn 422 calibrated ``spectral templates'' for stars withspectral types in the ranges G9.5-K3.5 III and K4.5-M0.5 III. Wenormalize each template by photometry for the individual stars usingpublished and/or newly secured near- and mid-infrared photometryobtained through fully characterized, absolutely calibrated,combinations of filter passband, detector radiance response, and meanterrestrial atmospheric transmission. These templates continue ourongoing effort to provide an all-sky network of absolutely calibrated,spectrally continuous, stellar standards for general infrared usage, allwith a common, traceable calibration heritage. The wavelength coverageis ideal for calibration of many existing and proposed ground-based,airborne, and satellite sensors, particularly low- tomoderate-resolution spectrometers. We analyze the statistics of probableuncertainties, in the normalization of these templates to actualphotometry, that quantify the confidence with which we can assert thatthese templates truly represent the individual stars. Each calibratedtemplate provides an angular diameter for that star. These radiometricangular diameters compare very favorably with those directly observedacross the range from 1.6 to 21 mas.
| Classification and Identification of IRAS Sources with Low-Resolution Spectra IRAS low-resolution spectra were extracted for 11,224 IRAS sources.These spectra were classified into astrophysical classes, based on thepresence of emission and absorption features and on the shape of thecontinuum. Counterparts of these IRAS sources in existing optical andinfrared catalogs are identified, and their optical spectral types arelisted if they are known. The correlations between thephotospheric/optical and circumstellar/infrared classification arediscussed.
| DDO photometry of E-region stars and equatorial standards - II This paper deals with the observations of 72 of McClure's equatorialstandard stars, made with the same photometer and DDO filters as wereused for the E-region stars in Cousins' Paper I in order to standardizethe observations. These observations were reduced in the natural systemand later transformed into McClure's system. Zero-point ties between theequatorial and E-region stars were also needed to standardize the lattersystem. With the exception of C(38-41), our photometry agrees as wellwith McClure's standard system as his own observations do, but both showsome small, apparently systematic, differences which are almostinevitable with a system like the DDO unless the response functions arevery well matched. Comparisons with 17 of Dean's measurements ofE-region stars show good agreement (~2 mmag) for the averagedzero-points, but there are small colour differences affecting C(35-38)and C(38-41) because of differences between the filters and thereduction procedures. This paper also deals with several problems in theDDO photometry that have implications for precision photometry ingeneral.
| Vitesses radiales. Catalogue WEB: Wilson Evans Batten. Subtittle: Radial velocities: The Wilson-Evans-Batten catalogue. We give a common version of the two catalogues of Mean Radial Velocitiesby Wilson (1963) and Evans (1978) to which we have added the catalogueof spectroscopic binary systems (Batten et al. 1989). For each star,when possible, we give: 1) an acronym to enter SIMBAD (Set ofIdentifications Measurements and Bibliography for Astronomical Data) ofthe CDS (Centre de Donnees Astronomiques de Strasbourg). 2) the numberHIC of the HIPPARCOS catalogue (Turon 1992). 3) the CCDM number(Catalogue des Composantes des etoiles Doubles et Multiples) byDommanget & Nys (1994). For the cluster stars, a precise study hasbeen done, on the identificator numbers. Numerous remarks point out theproblems we have had to deal with.
| Second astrolabe catalogue of Santiago. Positions for 350 FK5 and 164 FK5 Extension stars as determined with theDanjon astrolabe of Santiago and differences astrolabe-catalogue aregiven for Equinox J2000.0 and for the mean observation epoch of eachstar. The average mean error in alpha is +/-0.005s and +/-0.07" indelta. The mean epoch of observation of the catalogue is J1979.96.
| DDO photometry of E-region stars and equatorial standards (paper I). Not Available
| Santiago Fundamental Catalogue - A catalogue of 1105 FK5 stars (equinox J2000.0) The positions in right ascension and declination of 1105 FK5 stars,observed with a Meridian Circle during the period 1979 to 1991, aregiven. The average mean square error of a position, for the wholecatalog, is +/- 0.009 s in right ascension and +/- 0.10 arcsec indeclination. The mean epoch of the catalog is 1983.148.
| Santiago declination catalogue. II - A declination catalogue of 493 FK5 stars (equinox J2000.0) Abstract image available at:http://adsabs.harvard.edu/cgi-bin/nph-bib_query?1991A&AS...90..109C&db_key=AST
| Secondary standards for H-beta photometry in the Southern Hemisphere (second series). Not Available
| Physical data of the fundamental stars. Not Available
| UBV (RI)c standard stars in the E- and F-regions and in the Magellanic Clouds - a revised catalogue. Not Available
| Large and Kinematically Unbiased Samples of G- and K-Type Stars. III. Evolved Young Disk Stars in the Bright Star Sample Abstract image available at:http://adsabs.harvard.edu/cgi-bin/nph-bib_query?1989PASP..101...54E&db_key=AST
| Large and kinematically unbiased samples of G- and K-type stars. II - Observations of evolved stars in the Bright Star sample. III - Evolved young disk stars in the Bright Star sample Four color and RI observations were obtained for a large sample ofG-type and K-type stars in the Bright Star Catalogue. Data are firstpresented for 110 evolved stars. Photometry of evolved young diskpopulation stars have then been calibrated for luminosity, reddening,and metallicity on the basis of results for members of the Hyades andSirius superclusters. New DDO results are given for 120 stars.
| Secondary standards for the Stromgren UVBY system Observations of 158 E region stars have been made in the Stromgrensystem, using the 46-cm reflector at Cape Town. They are mostly brighterthan eighth magnitude and are intended for use as secondary standardsfor the four-color system. The E region relative zero points are definedwith a precision of + or - 0.001 mag, and the internal standard errorsof the colors life between + or - 0.001 and + or - 0.002 mag.
| A photometric survey of the bright southern Be stars Repeated UBV photometric measurements were made of the 86 bright Bestars south of declination -20 deg, and a network of comparison starswas set up. From a statistical study of the differential photometry itwas found that short- or intermediate-term variability seems to beoccurring in about half of the Be stars, and to be more evident in thestars of earlier spectral type. It was also possible to identify 11individual short- or intermediate-term variables. Four of these (all ofearly B spectral type) appear to exhibit significant variability on atime-scale of a day or less. More intensive observations of one of thesestars, 28 Omega CMA, indicate short-term variations consistent with thepublished spectroscopic period of 1.37 day.
| Discovery of three new RS Canum Venaticorum-like counterparts to HEAO I X-ray sources The identification of three high-latitude HEAO I Scanning ModulationCollimator X-ray sources with the chromospherically active RS CVn-likestars HD 113816, HD 146413, and HD 39576 is reported. Opticalobservations, including coude spectroscopy and broad-band and narrowband photoelectric photometry are presented. The Ca II emission strengthof all three stars shows that they are chromospherically active. HD146413 and HD 39576 exhibit variable X-ray emission in the 1-13 keVenergy range, while HD 113816 is a softer and steadier source. The levelof X-ray flux detected from these three stars is some one to two ordersof magnitude higher than predicted empirically from the Ca II emissionfluxes. It is proposed that this emission results from flarelikeactivity.
| Santiago declination catalogue - A declination catalogue of 412 FK4 stars (equinox 1950.0) This catalog contains the positions in declination, of 412 FK4 stars.The observations were carried out with the Repsold Meridian Circle atCerro Calan National Astronomical Observatory, during the period1963-1968. The average mean square error of one observation (for thewhole catalog) is + or - 0.13 arcsec. The mean epoch of observation ofthe catalog is 1965.75.
|
Submit a new article
Related links
Submit a new link
Member of following groups:
|
Observation and Astrometry data
Constellation: | Centaure |
Right ascension: | 11h51m08.70s |
Declination: | -45°10'25.0" |
Apparent magnitude: | 4.46 |
Distance: | 142.248 parsecs |
Proper motion RA: | -73.2 |
Proper motion Dec: | -8.3 |
B-T magnitude: | 6.139 |
V-T magnitude: | 4.609 |
Catalogs and designations:
|