Contingut
Imatges
Carregar la teva Imatge
DSS Images Other Images
Articles Relacionats
Coudé-feed stellar spectral library - atmospheric parameters Context. Empirical libraries of stellar spectra play an important rolein different fields. For example, they are used as reference for theautomatic determination of atmospheric parameters, or for buildingsynthetic stellar populations to study galaxies. The CFLIB(Coudé-feed library, Indo-US) database is at present one of themost complete libraries, in terms of its coverage of the atmosphericparameters space (T{eff}, log g and [Fe/H]) and wavelengthcoverage 3460-9464 Å at a resolution of 1 Å FWHM. Althoughthe atmospheric parameters of most of the stars were determined fromdetailed analyses of high-resolution spectra, for nearly 300 of the 1273stars of the library at least one of the three parameters is missing.For the others, the measurements, compiled from the literature, areinhomogeneous. Aims: In this paper, we re-determine theatmospheric parameters, directly using the CFLIB spectra, and comparethem to the previous studies. Methods: We use the ULySS programto derive the atmospheric parameters, using the ELODIE library as areference. Results: Based on comparisons with several previousstudies we conclude that our determinations are unbiased. For the 958 F,G, and K type stars the precision on T{eff}, log g, and[Fe/H] is respectively 43 K, 0.13 dex and 0.05 dex. For the 53 M starsthey are 82 K, 0.22 dex and 0.28 dex. And for the 260 OBA type stars therelative precision on T{eff} is 5.1%, and on log g, and[Fe/H] the precision is respectively 0.19 dex and 0.16 dex. Theseparameters will be used to re-calibrate the CFLIB fluxes and to producesynthetic spectra of stellar populations.Tables 2 and 3 are only available in electronic form at the CDS viaanonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/525/A71
| An absolutely calibrated Teff scale from the infrared flux method. Dwarfs and subgiants Various effective temperature scales have been proposed over the years.Despite much work and the high internal precision usually achieved,systematic differences of order 100 K (or more) among various scales arestill present. We present an investigation based on the infrared fluxmethod aimed at assessing the source of such discrepancies and pin downtheir origin. We break the impasse among different scales by using alarge set of solar twins, stars which are spectroscopically andphotometrically identical to the Sun, to set the absolute zero point ofthe effective temperature scale to within few degrees. Our newlycalibrated, accurate and precise temperature scale applies to dwarfs andsubgiants, from super-solar metallicities to the most metal-poor starscurrently known. At solar metallicities our results validatespectroscopic effective temperature scales, whereas for [Fe/H]? -2.5our temperatures are roughly 100 K hotter than those determined frommodel fits to the Balmer lines and 200 K hotter than those obtained fromthe excitation equilibrium of Fe lines. Empirical bolometric correctionsand useful relations linking photometric indices to effectivetemperatures and angular diameters have been derived. Our results takefull advantage of the high accuracy reached in absolute calibration inrecent years and are further validated by interferometric angulardiameters and space based spectrophotometry over a wide range ofeffective temperatures and metallicities.Table 8 is only available in electronic form at the CDS via anonymousftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/512/A54
| Structure and Evolution of Nearby Stars with Planets. II. Physical Properties of ~1000 Cool Stars from the SPOCS Catalog We derive detailed theoretical models for 1074 nearby stars from theSPOCS (Spectroscopic Properties of Cool Stars) Catalog. The Californiaand Carnegie Planet Search has obtained high-quality (R~=70,000-90,000,S/N~=300-500) echelle spectra of over 1000 nearby stars taken with theHamilton spectrograph at Lick Observatory, the HIRES spectrograph atKeck, and UCLES at the Anglo Australian Observatory. A uniform analysisof the high-resolution spectra has yielded precise stellar parameters(Teff, logg, vsini, [M/H], and individual elementalabundances for Fe, Ni, Si, Na, and Ti), enabling systematic erroranalyses and accurate theoretical stellar modeling. We have created alarge database of theoretical stellar evolution tracks using the YaleStellar Evolution Code (YREC) to match the observed parameters of theSPOCS stars. Our very dense grids of evolutionary tracks eliminate theneed for interpolation between stellar evolutionary tracks and allowprecise determinations of physical stellar parameters (mass, age,radius, size and mass of the convective zone, surface gravity, etc.).Combining our stellar models with the observed stellar atmosphericparameters and uncertainties, we compute the likelihood for each set ofstellar model parameters separated by uniform time steps along thestellar evolutionary tracks. The computed likelihoods are used for aBayesian analysis to derive posterior probability distribution functionsfor the physical stellar parameters of interest. We provide a catalog ofphysical parameters for 1074 stars that are based on a uniform set ofhigh-quality spectral observations, a uniform spectral reductionprocedure, and a uniform set of stellar evolutionary models. We explorethis catalog for various possible correlations between stellar andplanetary properties, which may help constrain the formation anddynamical histories of other planetary systems.
| Medium-resolution Isaac Newton Telescope library of empirical spectra - II. The stellar atmospheric parameters We present a homogeneous set of stellar atmospheric parameters(Teff, logg, [Fe/H]) for MILES, a new spectral stellarlibrary covering the range λλ 3525-7500Å at2.3Å (FWHM) spectral resolution. The library consists of 985 starsspanning a large range in atmospheric parameters, from super-metal-rich,cool stars to hot, metal-poor stars. The spectral resolution, spectraltype coverage and number of stars represent a substantial improvementover previous libraries used in population synthesis models. Theatmospheric parameters that we present here are the result of aprevious, extensive compilation from the literature. In order toconstruct a homogeneous data set of atmospheric parameters we have takenthe sample of stars of Soubiran, Katz & Cayrel, which has very welldetermined fundamental parameters, as the standard reference system forour field stars, and have calibrated and bootstrapped the data fromother papers against it. The atmospheric parameters for our clusterstars have also been revised and updated according to recent metallicityscales, colour-temperature relations and improved set of isochrones.
| Accurate fundamental parameters for lower main-sequence stars We derive an empirical effective temperature and bolometric luminositycalibration for G and K dwarfs, by applying our own implementation ofthe Infrared Flux Method to multiband photometry. Our study is based on104 stars for which we have excellent BV(RI)C JHKSphotometry, excellent parallaxes and good metallicities.Colours computed from the most recent synthetic libraries (ATLAS9 andMARCS) are found to be in good agreement with the empirical colours inthe optical bands, but some discrepancies still remain in the infrared.Synthetic and empirical bolometric corrections also show fair agreement.A careful comparison to temperatures, luminosities and angular diametersobtained with other methods in the literature shows that systematiceffects still exist in the calibrations at the level of a few per cent.Our Infrared Flux Method temperature scale is 100-K hotter than recentanalogous determinations in the literature, but is in agreement withspectroscopically calibrated temperature scales and fits well thecolours of the Sun. Our angular diameters are typically 3 per centsmaller when compared to other (indirect) determinations of angulardiameter for such stars, but are consistent with the limb-darkeningcorrected predictions of the latest 3D model atmospheres and also withthe results of asteroseismology.Very tight empirical relations are derived for bolometric luminosity,effective temperature and angular diameter from photometric indices.We find that much of the discrepancy with other temperature scales andthe uncertainties in the infrared synthetic colours arise from theuncertainties in the use of Vega as the flux calibrator. Angulardiameter measurements for a well-chosen set of G and K dwarfs would go along way to addressing this problem.
| Pulkovo compilation of radial velocities for 35495 stars in a common system. Not Available
| Medium-resolution Isaac Newton Telescope library of empirical spectra A new stellar library developed for stellar population synthesismodelling is presented. The library consists of 985 stars spanning alarge range in atmospheric parameters. The spectra were obtained at the2.5-m Isaac Newton Telescope and cover the range λλ3525-7500 Å at 2.3 Å (full width at half-maximum) spectralresolution. The spectral resolution, spectral-type coverage,flux-calibration accuracy and number of stars represent a substantialimprovement over previous libraries used in population-synthesis models.
| Effective temperature scale and bolometric corrections from 2MASS photometry We present a method to determine effective temperatures, angularsemi-diameters and bolometric corrections for population I and II FGKtype stars based on V and 2MASS IR photometry. Accurate calibration isaccomplished by using a sample of solar analogues, whose averagetemperature is assumed to be equal to the solar effective temperature of5777 K. By taking into account all possible sources of error we estimateassociated uncertainties to better than 1% in effective temperature andin the range 1.0-2.5% in angular semi-diameter for unreddened stars.Comparison of our new temperatures with other determinations extractedfrom the literature indicates, in general, remarkably good agreement.These results suggest that the effective temperaure scale of FGK starsis currently established with an accuracy better than 0.5%-1%. Theapplication of the method to a sample of 10 999 dwarfs in the Hipparcoscatalogue allows us to define temperature and bolometric correction (Kband) calibrations as a function of (V-K), [m/H] and log g. Bolometriccorrections in the V and K bands as a function of T_eff, [m/H] and log gare also given. We provide effective temperatures, angularsemi-diameters, radii and bolometric corrections in the V and K bandsfor the 10 999 FGK stars in our sample with the correspondinguncertainties.
| Spectroscopic Properties of Cool Stars (SPOCS). I. 1040 F, G, and K Dwarfs from Keck, Lick, and AAT Planet Search Programs We present a uniform catalog of stellar properties for 1040 nearby F, G,and K stars that have been observed by the Keck, Lick, and AAT planetsearch programs. Fitting observed echelle spectra with synthetic spectrayielded effective temperature, surface gravity, metallicity, projectedrotational velocity, and abundances of the elements Na, Si, Ti, Fe, andNi, for every star in the catalog. Combining V-band photometry andHipparcos parallaxes with a bolometric correction based on thespectroscopic results yielded stellar luminosity, radius, and mass.Interpolating Yonsei-Yale isochrones to the luminosity, effectivetemperature, metallicity, and α-element enhancement of each staryielded a theoretical mass, radius, gravity, and age range for moststars in the catalog. Automated tools provide uniform results and makeanalysis of such a large sample practical. Our analysis method differsfrom traditional abundance analyses in that we fit the observed spectrumdirectly, rather than trying to match equivalent widths, and wedetermine effective temperature and surface gravity from the spectrumitself, rather than adopting values based on measured photometry orparallax. As part of our analysis, we determined a new relationshipbetween macroturbulence and effective temperature on the main sequence.Detailed error analysis revealed small systematic offsets with respectto the Sun and spurious abundance trends as a function of effectivetemperature that would be inobvious in smaller samples. We attempted toremove these errors by applying empirical corrections, achieving aprecision per spectrum of 44 K in effective temperature, 0.03 dex inmetallicity, 0.06 dex in the logarithm of gravity, and 0.5 kms-1 in projected rotational velocity. Comparisons withprevious studies show only small discrepancies. Our spectroscopicallydetermined masses have a median fractional precision of 15%, but theyare systematically 10% higher than masses obtained by interpolatingisochrones. Our spectroscopic radii have a median fractional precisionof 3%. Our ages from isochrones have a precision that variesdramatically with location in the Hertzsprung-Russell diagram. We planto extend the catalog by applying our automated analysis technique toother large stellar samples.
| Chromospheric Ca II Emission in Nearby F, G, K, and M Stars We present chromospheric Ca II H and K activity measurements, rotationperiods, and ages for ~1200 F, G, K, and M type main-sequence stars from~18,000 archival spectra taken at Keck and Lick Observatories as a partof the California and Carnegie Planet Search Project. We have calibratedour chromospheric S-values against the Mount Wilson chromosphericactivity data. From these measurements we have calculated medianactivity levels and derived R'HK, stellar ages,and rotation periods from general parameterizations for 1228 stars,~1000 of which have no previously published S-values. We also presentprecise time series of activity measurements for these stars.Based on observations obtained at Lick Observatory, which is operated bythe University of California, and on observations obtained at the W. M.Keck Observatory, which is operated jointly by the University ofCalifornia and the California Institute of Technology. The KeckObservatory was made possible by the generous financial support of theW. M. Keck Foundation.
| The Indo-US Library of Coudé Feed Stellar Spectra We have obtained spectra for 1273 stars using the 0.9 m coudéfeed telescope at Kitt Peak National Observatory. This telescope feedsthe coudé spectrograph of the 2.1 m telescope. The spectra havebeen obtained with the no. 5 camera of the coudé spectrograph anda Loral 3K×1K CCD. Two gratings have been used to provide spectralcoverage from 3460 to 9464 Å, at a resolution of ~1 Å FWHMand at an original dispersion of 0.44 Å pixel-1. For885 stars we have complete spectra over the entire 3460 to 9464 Åwavelength region (neglecting small gaps of less than 50 Å), andpartial spectral coverage for the remaining stars. The 1273 stars havebeen selected to provide broad coverage of the atmospheric parametersTeff, logg, and [Fe/H], as well as spectral type. The goal ofthe project is to provide a comprehensive library of stellar spectra foruse in the automated classification of stellar and galaxy spectra and ingalaxy population synthesis. In this paper we discuss thecharacteristics of the spectral library, viz., details of theobservations, data reduction procedures, and selection of stars. We alsopresent a few illustrations of the quality and information available inthe spectra. The first version of the complete spectral library is nowpublicly available from the National Optical Astronomy Observatory(NOAO) via ftp and http.
| Improved Astrometry and Photometry for the Luyten Catalog. II. Faint Stars and the Revised Catalog We complete construction of a catalog containing improved astrometry andnew optical/infrared photometry for the vast majority of NLTT starslying in the overlap of regions covered by POSS I and by the secondincremental Two Micron All Sky Survey (2MASS) release, approximately 44%of the sky. The epoch 2000 positions are typically accurate to 130 mas,the proper motions to 5.5 mas yr-1, and the V-J colors to0.25 mag. Relative proper motions of binary components are measured to 3mas yr-1. The false-identification rate is ~1% for11<~V<~18 and substantially less at brighter magnitudes. Theseimprovements permit the construction of a reduced proper-motion diagramthat, for the first time, allows one to classify NLTT stars intomain-sequence (MS) stars, subdwarfs (SDs), and white dwarfs (WDs). We inturn use this diagram to analyze the properties of both our catalog andthe NLTT catalog on which it is based. In sharp contrast to popularbelief, we find that NLTT incompleteness in the plane is almostcompletely concentrated in MS stars, and that SDs and WDs are detectedalmost uniformly over the sky δ>-33deg. Our catalogwill therefore provide a powerful tool to probe these populationsstatistically, as well as to reliably identify individual SDs and WDs.
| Radial Velocities for 889 Late-Type Stars We report radial velocities for 844 FGKM-type main-sequence and subgiantstars and 45 K giants, most of which had either low-precision velocitymeasurements or none at all. These velocities differ from the standardstars of Udry et al. by 0.035 km s-1 (rms) for the 26 FGKstandard stars in common. The zero point of our velocities differs fromthat of Udry et al.: =+0.053km s-1. Thus, these new velocities agree with the best knownstandard stars both in precision and zero point, to well within 0.1 kms-1. Nonetheless, both these velocities and the standardssuffer from three sources of systematic error, namely, convectiveblueshift, gravitational redshift, and spectral type mismatch of thereference spectrum. These systematic errors are here forced to be zerofor G2 V stars by using the Sun as reference, with Vesta and day sky asproxies. But for spectral types departing from solar, the systematicerrors reach 0.3 km s-1 in the F and K stars and 0.4 kms-1 in M dwarfs. Multiple spectra were obtained for all 889stars during 4 years, and 782 of them exhibit velocity scatter less than0.1 km s-1. These stars may serve as radial velocitystandards if they remain constant in velocity. We found 11 newspectroscopic binaries and report orbital parameters for them. Based onobservations obtained at the W. M. Keck Observatory, which is operatedjointly by the University of California and the California Institute ofTechnology, and on observations obtained at the Lick Observatory, whichis operated by the University of California.
| A search for previously unrecognized metal-poor subdwarfs in the Hipparcos astrometric catalogue We have identified 317 stars included in the Hipparcos astrometriccatalogue that have parallaxes measured to a precision of better than 15per cent, and the location of which in the(MV,(B-V)T) diagram implies a metallicitycomparable to or less than that of the intermediate-abundance globularcluster M5. We have undertaken an extensive literature search to locateStrömgren, Johnson/Cousins and Walraven photometry for over 120stars. In addition, we present new UBV(RI)C photometry of 201of these candidate halo stars, together with similar data for a further14 known metal-poor subdwarfs. These observations provide the firstextensive data set of RCIC photometry ofmetal-poor, main-sequence stars with well-determined trigonometricparallaxes. Finally, we have obtained intermediate-resolution opticalspectroscopy of 175 stars. 47 stars still lack sufficient supplementaryobservations for population classification; however, we are able toestimate abundances for 270 stars, or over 80 per cent of the sample.The overwhelming majority have near-solar abundance, with theirinclusion in the present sample stemming from errors in the colourslisted in the Hipparcos catalogue. Only 44 stars show consistentevidence of abundances below [Fe/H]=-1.0. Nine are additions to thesmall sample of metal-poor subdwarfs with accurate photometry. Weconsider briefly the implication of these results for clustermain-sequence fitting.
| Catalogue of [Fe/H] determinations for FGK stars: 2001 edition The catalogue presented here is a compilation of published atmosphericparameters (Teff, log g, [Fe/H]) obtained from highresolution, high signal-to-noise spectroscopic observations. This newedition has changed compared to the five previous versions. It is nowrestricted to intermediate and low mass stars (F, G and K stars). Itcontains 6354 determinations of (Teff, log g, [Fe/H]) for3356 stars, including 909 stars in 79 stellar systems. The literature iscomplete between January 1980 and December 2000 and includes 378references. The catalogue is made up of two tables, one for field starsand one for stars in galactic associations, open and globular clustersand external galaxies. The catalogue is distributed through the CDSdatabase. Access to the catalogue with cross-identification to othersets of data is also possible with VizieR (Ochsenbein et al.\cite{och00}). The catalogue (Tables 1 and 2) is only available inelectronic form at the CDS via anonymous ftp to cdsarc.u-strasbg.fr(130.79.128.5) or viahttp://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/373/159 and VizieRhttp://vizier.u-strasbg.fr/.
| High-Resolution Abundance Analysis of Very Metal-rich Stars in the Solar Neighborhood We report detailed analysis of high-resolution spectra of nine highvelocity metal-rich dwarfs in the solar neighborhood, selected from theproper motion samples of Grenon. The stars are super metal-rich, and 5of them have fe >= +0.4, making them the most metal-rich starscurrently known. We find that alpha -elements decrease with increasingmetallicity; s-elements are underabundant by about [s-elements/Fe] ~-0.3; the ion{Eu}{2} line was measurable for 6 stars, showing [Eu/Fe] ~0.0, except for G161-29 where [Eu/Fe] = +0.50. All calculations followedthe same methods used by Castro et al. (1996) [AJ, 111, 2439] for theanalysis of the well-known metal-rich prototype mul and the verystrong-lined bulge star bww, for which fe =+0.46 and +0.47 were foundrespectively. While exceeding the [Fe/H] of current bulge samples, thechemistry of these stars has important similarities and differences. Thenear-solar abundances of the alpha-capture elements places these starson the metal-rich extension of McWilliam & Rich (1994) [ApJS, 91,749], but their s-process abundances are much lower than those of thebulge giants. These low s-process values have been interpreted as thehallmark of an ancient stellar population. We are unable to convincinglyassign these stars to a known Galactic population and we urge furtherstudies of larger samples.
| Dwarf K and M stars in the southern hemisphere. Abstract image available at:http://adsabs.harvard.edu/cgi-bin/nph-bib_query?1972AJ.....77..486U&db_key=AST
|
Enviar un nou article
Enllaços Relacionats
- - No s'ha trobat enllaços -
Enviar un nou enllaç
Membre dels grups següents:
|
Dades d'Observació i Astrometria
Constel·lació: | Ophiucus |
Ascensió Recta: | 16h23m26.91s |
Declinació: | -11°35'40.6" |
Magnitud Aparent: | 10.455 |
Distancia: | 48.379 parsecs |
Moviment propi RA: | -152.5 |
Moviment propi Dec: | -119 |
B-T magnitude: | 11.613 |
V-T magnitude: | 10.551 |
Catàlegs i designacions:
|