Inici     Començant     Sobreviure a l'Univers    
Inhabited Sky
    News@Sky     Astro Fotografia     La Col·lecció     Fòrum     Blog New!     FAQ     Premsa     Login  

HD 21634


Contingut

Imatges

Carregar la teva Imatge

DSS Images   Other Images


Articles Relacionats

Effective temperature scale and bolometric corrections from 2MASS photometry
We present a method to determine effective temperatures, angularsemi-diameters and bolometric corrections for population I and II FGKtype stars based on V and 2MASS IR photometry. Accurate calibration isaccomplished by using a sample of solar analogues, whose averagetemperature is assumed to be equal to the solar effective temperature of5777 K. By taking into account all possible sources of error we estimateassociated uncertainties to better than 1% in effective temperature andin the range 1.0-2.5% in angular semi-diameter for unreddened stars.Comparison of our new temperatures with other determinations extractedfrom the literature indicates, in general, remarkably good agreement.These results suggest that the effective temperaure scale of FGK starsis currently established with an accuracy better than 0.5%-1%. Theapplication of the method to a sample of 10 999 dwarfs in the Hipparcoscatalogue allows us to define temperature and bolometric correction (Kband) calibrations as a function of (V-K), [m/H] and log g. Bolometriccorrections in the V and K bands as a function of T_eff, [m/H] and log gare also given. We provide effective temperatures, angularsemi-diameters, radii and bolometric corrections in the V and K bandsfor the 10 999 FGK stars in our sample with the correspondinguncertainties.

Observed and computed spectral flux distribution of non-supergiant O9-G8 stars. III - Determination of T(eff) for the stars in the Breger Catalogue
The effective temperatures and angular diameters of nonsupergiant O9-G8stars are determined from visible spectrophotometry. The results, whichrefer to 302 stars included in the Breger Catalogue, are derived fromthe comparison between the observed flux distributions and thepredictions of Kurucz's models (1979). The uncertainties to be expectedin individual results are discussed; their sizes are of the order of 5percent in effective temperature and 10 percent in angular diameter.

Enviar un nou article


Enllaços Relacionats

  • - No s'ha trobat enllaços -
Enviar un nou enllaç


Membre dels grups següents:


Dades d'Observació i Astrometria

Constel·lació:Eridanus
Ascensió Recta:03h29m12.06s
Declinació:-12°05'10.1"
Magnitud Aparent:8.809
Distancia:149.477 parsecs
Moviment propi RA:-16.4
Moviment propi Dec:9.3
B-T magnitude:9.267
V-T magnitude:8.847

Catàlegs i designacions:
Noms Propis   (Edit)
HD 1989HD 21634
TYCHO-2 2000TYC 5299-1143-1
USNO-A2.0USNO-A2 0750-00771281
HIPHIP 16234

→ Sol·licitar més catàlegs i designacions de VizieR